Proceedings, Electrical engineering institute Nikola Tesla, vol. 22, 2012

  1. Generator Voltage Droop and Voltage-Reactive States of Transmission Networks, M. Ivanović, D.P. Popović, Đ. Stojić, S. Veinović, M. Milinković, D. Arnautović, S. Minić , pp. 1 (1-2012)
  2. The Operating Performance Tests of Power Unit A1 in HPP “Zvornik” in Load-Frequency Control, V. Stanojčić, D. Džepčeski, D. Arnautović S. Bogdanović, J. Pavlović, pp.  21 (2-2012)
  3. Mathematical Model of Transmission Network Static State Estimation, A. Ivanov, D. Đorđević, pp. 33 (3-2012)
  4. Models of Hydro Power Plant in Dynamic Security Analyses of Electric Power Interconnections, M. Ivanović, D.P. Popović, D. Arnautović, S. Bogdanović, D. Džepčeski, J. Dragosavac, J. Pavlović, S. Minić, pp. 43 (4-2012)
  5. Models of Generator Excitation Control Systems in Dynamic Security Analyses of Electric Power Interconnections, M Ivanović, D.P. Popović, Đ. Stojić, S. Veinović, D. Joksimović, S. Minić, pp. 69 (5-2012)
  6. Primary, Secondary and Tertiary Frequency Control in Dynamic Security Analyses of Electric Power Interconnections, M. Ivanović, D.P. Popović, S. Minić, pp.  93 (6-2012)
  7. Measurement of Definite Integral Product of Two or More Signals Using Two-Bit ADCs, Ličina, P. Sovilj, V. Vujičić, pp. 117 (7-2012)
  8. Experimental Research of the Effects of Different Shields on Power Frequency Electric Field Mitigation, J. Nahman, D. Salamon, M. Grbić, pp. 137 (8-2012)
  9. Determination of Regression Functions for the Charging and Discharging Processes of Valve Regulated Lead-Acid Batteries, V. Vukić, pp153 (9-2012)
  10. Experimental Research of the Effects of Different Shields on Power Frequency Magnetic Induction Mitigation, J. Nahman, D. Salamon, M. Grbić,pp. 173 (10-2012)
  11. Currents and Overvoltages Caused by Establishing and Interrupting of Ground Faults in 10 kV Network in the City of Nis, P. Vukelja, J. Mrvić, D. Hrvić, pp. 185 (11-2012)
  12. Characteristics and Possibilities of Software Tool for Metal-Oxide Surge Arresters Selection, DĐorđević, Z .Stojković, A. Ivanov, pp. 195 (12-2012)
  13. Interlaboratory Comparison of Measuring Results of Magnetic Field near 400 kV Overhead Power Line, M. Grbić, A. Pavlović, pp.  209 (13-2012)
  14. Ultrasonic Partial Discharge Monitoring Method On Instrument Transformers, N.  Kartalović, N. Ilić, A. Milošević, D. Teslić, N. Cakić, S. Milosavljević, pp. 223 (14-2012)
  15. The Advanced Eccentricity and Broken Cage Diagnostic Method for Medium Voltage Induction Motors, Ž. Janda, M. Janković, M. Milošević, B. Jovanović , pp.  235 (15-2012)
  16. System for magnetic monitoring of high voltage motors MM6212, N, Kartalović, B. Babić, N. Ilić, S.Milosavljević, pp.  251 (16-2012)